Strany 1 - Tank Sentinel

Tank SentinelProgramming GuideTS-5 SeriesSoftware Revision 0.5.0.7 Franklin Fueling Systems • 3760 Marsh Rd. • Madison, WI 53718 USATel: +1 608 838 8

Strany 2 - Open Source Notice

6Password InputTo modify console settings and change passwords, you must rst enter in the current Administrator password. The default password is, in

Strany 3 - Contents

7Conguring IP Settings for CommunicationBefore attempting to modify any computer settings, contact the Information Technologies department of your bu

Strany 4

8• In Classic View, click on Network Connections.4. Right-click on Local Area Connection and select Properties.

Strany 5 - Important Safety Messages

95. In the Local Area Connection Properties dialog box, under “This connection uses the following items,” select Internet Protocol (TCP/IP) and click

Strany 6 - Approvals

102. Select User Congured.3. Enter an IP address. For simplicity, make the last segment of the IP one number different than the IP address of the c

Strany 7 - Introduction

112. Enter an IP address. For simplicity, make the last segment of the IP one number different than the IP address of the console. Upon initial setup

Strany 8 - Related Documentation

123. Select Connect Directly to Another Computer.4. Select Guest.5. Enter a name under Computer Name (it can be the site name).6. Select the commu

Strany 9 - User Interfaces (UI)

139. In the Network Connections window, right-click the new direct connection that was created and select Properties.10. Under the General tab, sele

Strany 10 - Modifying Passwords

1415. Leave the existing Redialing Options as they are.16. Select the Security tab.17. Select Advanced (custom settings).18. Select the Networking

Strany 11

15Initial Console CongurationBefore the console can be used, an intial setup must rst be performed. This portion of the guide will instruct you on h

Strany 12

iiCopyright ©2006 by Intelligent Controls (INCON). No part of this publication may be reproduced in any form without the prior written consent of INC

Strany 13

16Translation OptionsLanguage EnglishSpanish (Español)Russian (Русский)Chinese (Simplied) (中文(简)Date/Time OptionsShort date formatMM/dd/yyyy M/d/yyy

Strany 14 - Use the Following IP Address

17Units OptionsVolumeLiters GallonsImperial GallonsLengthMillimeters Centimeters Meters InchesTemperatureCentigrade FahrenheitFlowLiters/Hour Cubic Ce

Strany 15 - Check Status of Connection

18Date/Time SetTo set the date and time, press the button that corresponds with your selection and select the correct option from the list. If your ch

Strany 16

19Programming and NavigationConsole NavigationThe operating system is designed so that a user may navigate with ease. Manageable applications allow th

Strany 17 - 13. Select the Options tab

20Character Navigation ButtonsWhen prompted to enter system information, press the corresponding keys.Character Selection: Selects between upper case

Strany 18 - Check Operation of Connection

21System IDGroup NameParameter NameParameter ValueDescriptionMax CharactersSystem IDSite Name (Site Name) Physical name of site. 40Web UI URL (http:/

Strany 19 - Initial Console Conguration

22Programming ModulesThe Fuel Management System is composed of a custom set of modules. Each module maintains individual characteristics. Parameters m

Strany 20

23AC Input ModulesGroup Name Parameter NameParameterValueDescription Max ValueAC Input Modules Number Gasoline Hooks per Dispenser (2) Including diese

Strany 21 - Conguration Menu

24Relay ModulesGroup Name Parameter Name Parameter Value Description Max ValueRelay Modules Module # Channels (0) Number of channels in use p

Strany 22 - Remote Logging Host

25Programming FMS ParametersHere is where specic equipment parameters will be modied to match the site setup.Fuel Management SystemGroup Name Parame

Strany 24 - Programming System Parameters

26Manifold Tank SystemGroup Name Parameter Name Parameter Value Description Max ValueFuel Management System Tanks Number of Tanks (0) Number of ta

Strany 25 - System Conguration

27Tank Sentinel Anyware (TSA)Navigating Applications RemotelyTSA offers several ways to navigate through applications: easy-to-read web pages that use

Strany 26 - Programming Modules

28Backup Conguration FilesDownloadBackup congurations allow you to download the setup le and store it on any PC or Laptop connected to the console.

Strany 27 - 4-20 mA Input Modules

294. To download a site conguration, click Download. A File Download dialog box may appear, and, if it does, select Save to open an explorer window.

Strany 28 - Relay Modules

302. Left-click once on Setup.3. To upload a conguration le, click Upload on the Setup page. At this point, the console may prompt for a password

Strany 29 - Programming FMS Parameters

31MiscellaneousLeak TestingAll TS-5 series console models meet (or exceed) the requirements of the U.S. Environment Protection Agency (EPA/530/UST-90/

Strany 30 - Manifold Tank System

321. To force a Static Tank Leak test, press the FMS button in the Application Window.2. Press the Application Menu button.3. Select the Control bu

Strany 31 - Tank Sentinel Anyware (TSA)

33Tank Leak Test ResultsLeak test results are either increase, passed, failed, or indeterminate.Reasons Why Tank Leak Tests Fail The tank leaks. Tempe

Strany 32 - Backup Conguration Files

34Reasons Why SCALD Tank Tests may Fail• Temperature • If a site is receiving deliveries frequently and the temperature of the fuel being delivered is

Strany 33

35Manually Forcing Line Leak TestsLines MUST be calibrated and enabled prior to forcing leak tests.1. To force a Line Leak test, press the FMS button

Strany 34

ivTank Sentinel Anyware (TSA) ...27Navigating Applications Rem

Strany 35 - Miscellaneous

36Line Leak Test ResultsLine Leak test results are either increase, passed, failed, or indeterminate.Reasons Why Line Leak Tests Fail The tank leaks.

Strany 36

37List of Alarms and TroubleshootingFor all alarms conditions, the troubleshooting steps provided in this chapter are suggested actions to take in the

Strany 37 - SCALD Tank Leak Tests

38Displayed Alarm / Warning Device Description Recommended ActionsDispensing Test Failed Line When pump is turned on, a pressure test is started. Afte

Strany 38

39Displayed Alarm / Warning Device Description Recommended ActionsLow battery Tank Backup battery is low. See Installation Guide for replacement instr

Strany 39

40Displayed Alarm / Warning Device Description Recommended ActionsProbe Module Setup Error None Programming errors made during setup of the Probe Modu

Strany 40

41Displayed Alarm / Warning Device Description Recommended ActionsSN3 Sump Full ChannelSN3 3-wire sensor detected sump full of liquid.Visually inspect

Strany 41

42Appendix A - Standard Tanks TableLegendO/C = Owens Corning / FC Fluid ContainmentD = Diameter (Dia.)L = LengthS = Single WallDW = Double Wall Tank (

Strany 42 - Warning

43Type #Manufacturer Model Capacity (Gallons)DimensionsD x L (inches)S / DW Wall27 Xerxes — 3,000 96 x 147 S28 Xerxes — 4,000 75 x 263 S29 Xerxes —

Strany 43

Appendix B - Standard Products Table Product Name API Gravity (6B Compensation)Leaded Regular 63.5Unleaded Regular 63.5Unleaded Plus 62.8Unleaded Extr

Strany 44

1Important Safety MessagesINCON equipment is designed to be installed in association with volatile hydrocarbon liquids such as gasoline and diesel fue

Strany 45

2Certied Programmer/Service Person: Only an INCON certied programmer or service person is allowed to access both the user interface keypad and areas

Strany 46

3IntroductionThe purpose of this manual is to guide installers, operators and technicians through programming and troubleshooting theTS-5 console, so

Strany 47

4Denitions and AcronymsModule – A module is a plug-in card within the TS-5 series console that is used to perform various functions of the console.

Strany 48

5GeneralAfter the Fuel Management System has been installed, typically your interaction with the system will be from the LCD display, on-board printer